| Specifications | |
| Output Power | 75W Continuous Power, 150W Surge Power |
| Standby Current | DC 12V smaller than 0.21A |
| Input Voltage | DC 10V-15V |
| Output Voltage | AC 230V |
| Output Waveform | Modified Sine Wave |
| Efficiency | 90% |
| Initial Checking | Auto-Detecting wrong input voltage |
| Output Regulation | ±5% Intelligent AVR |
| Output Frequency | 50Hz ±0.05% Crystal Controlled |
| Protections: | |
| Output Short | Output short circuit protection |
| BatteryLow | <11V ± 0.5V pre-alarm |
| <10V ± 0.5V shut down & alarm | |
| Over Heating | >60° Pre-alarm |
| >65° Shut down & alarm | |
| Over Load | >150W Pre-alarm |
| >200W Shut down & alarm | |
| Battery Polarity Reverse | By fuse |
| Fuse | DC12V: 15A*1PC |
| AC Outlet | 1 x AC Outlet |
| Dimension (LxWxH) | 120*73*73 (mm) |
| Net Weight | 0.56 kgs |